User's Manual

Synchronization
T2300 Slave T2300 Master
Sweep freq. tuning
Put EAS detector above transmitter, press “power” to detect:
Fc: read 7.6~8.2MHz (VR15 for tuning)
Fs: should read 180Hz when JP7 is connected;
Δshould read 1000±50KHz (VR14 for tuning).
Receiver antenna Rx 4300Refer to figure 6
Technical Data:
Operating voltage….…………. DC 24V
Operating current, stand-by…… < 300mA
Operating current, operating….. < 400mA
Fuse…………………………… 250V, 500mA
Slide switches setting
RF Labels and Hard Tags
Selector
Labels and Hard
tags (factory setting)
Hard tags only
SW1-1 ON OFF
Modulation Frequency
180Hz(factory
setting)
172Hz 160Hz 150Hz
SW1-2 ON On OFF OFF
SW1-3 ON OFF ON OFF
The modulation frequency in the Receiver Antenna must be the same as that in the Transmitter Antenna.
Sensitivity Level Highest (factory
setting)
High Medium Low
SW1-4 ON OFF ON OFF
SW1-5 ON ON OFF OFF
Detecting Moving and
Stationery tags
Detect both moving
and stationery tags
Detect moving
tags only
P4
P3
P4
P3
P3
JP2, JP3 in 1 & 2
position respectively
(
factor
y
settin
g)
.
Change slave
setting in JP2, JP3
to 2 & 3 position
Connect to
another slave
via P3.
Connect to another
slave via P3.