User's Manual
SAVEandLOAD
LOAD:willtransmitthelatestsettingtothePCBbut itwillnotSAVE.Itisusedtocheckperformancebased
onchangesbutwhenmachineisturnedoff,thelatestsettingwillnotbesaved.
SAVE:afterLOADthenpressSAVEandthelatestsettingwillbesavedandoperatewhenmachinerestarts.
Under[Set‐up],therearesevensettings:‐
1, TransmissionSetting
Centerfrequency:8.2factorysetting,others8.6,9.0,9.5
Frequencyrange:7.6~8.7factorysetting,rangefrom7.4~10
Mode:n.a.
On/Off:ON,whenlabelisdetected,transmissionpowerwillreduce
OFF,
nochangetotransmissionpower(factorysetting)
2, ReceiverSetting