User's Manual

SoftwareTuning
Innormalcircumstances,thereisnoneedforsoftwareadjustmentsasatfactorysetting,theelectronicsareset
to the optimal level. However, should the environmental condition differ significantly or there are strong
interference,changingthesystemsettingsviasoftwaremayenhancesystemoperation.
a, Priortousingthesoftware:
J102 inPCBshould beshortcirculated by placingplastic cap. Once adjustment ismade,the plasticcapin
J102shouldbedisconnected.
b, ResettoFactorySetting:
1. short circuit J102 by placing plastic cap
2. short circuit 5& 6 at J203 by placing plastic cap
3. press RESET and allow PCB to restart
4. when self-testing completes, disconnect the plastic cap in 5&6 at J203.
5. disconnect the plastic cap in J102
6. press RESET again
c, USBConnection:
ConnectoneendoftheUSBtothecomputerand
theotherendtothePCB.
Open the software program and the software will indicate available COMM drive. Select desired COMM
driveandwhenallconnectedproperly,SuccessfulConnectionwillshow.
d, Menu:
Therearefiveheadings:[Parameterset ting],[Parameterquery],[Datadisplay],[Recorddata]and[Setting]:
J104
J101
J102
Reset
J300