User's Manual

Note:
NOTES:
1. Shielded twisted pair cable should be used for connection.
2. The maximum distance of the whole interconnection is 50m, i.e. the connection distance count from the first
antenna to the last antenna should be less than 50m.
3. Each set of antennae can have only one Master and the other Slaves. One Master antenna can link with a
maximum of 30 Slave antennae.
4. Distance of each synchronization cable should not be more than 30cm from main cable.
MasterAntennaeSetup
SelectanyoneoftheantennaeasMasterandinthatPCB,J203,shortcircuit7&8byplacingplasticcapasshown
below.IntheRedselectornexttoJ203,chooseonenumberoutof1
to6andturntoON.Inthediagrambelow,1
isselected.IfthereisanothersetofantennaewithanotherMaster,adifferentnumbershouldbeused.
SlaveAntennaSetup
FortheSlaves,donotshortcircuitanyoneoftheconnectorsatJ203above.
Inthe
RedselectornexttoJ203,selectthesamenumbertoONpositionasperMaster.Inthediagramabove,1is
selected.ForanothersetwithdifferentMaster,usethenumberasindicatedinthatparticularMaster.
Synchronization
J104istheconnectorforsynchronization.Therearethreecolorsonit:‐
Black
: GND (connecttoshieldedlayerofthetwistedpaircable)
Red : SH (connecttohighsignalcable)
White : SL (connecttolowsignalcable)
At either end of the multiple connections (namely, the first and the last antenna), J101 needs to be short
circulatedi.e.closingwithaplasticcap.
J203