User's Manual
TR7600 RF Transceiver
Summary
Normal conditions
Operating temperature : 0°C ~ 40°C
Storage temperature : - 40°C ~ 60°C
Humidity : 5% ~ 95%
Technical Specifications
Operatingvoltage :24VDC
Operatingcurrent :400+/‐30Ma(max)
Safetyfuse :250V,1A(delay)
Operatingfrequency :centerfrequency8.2MHz(adjustable7.6~8.9MHz)
Detectionspeed :
≥2m/s
Power Supply
EG107:built‐inpowersupplyPCB,onepowersupplyperantenna
Inputvoltage :120VAC50/60Hz(voltagerange187~242VAC)
Outputvoltage :24VAC1400mA
Wireconnection :30m(max,Ø0.3mm)
Detection
TR7600 PCB can be used in EG2266, EG2268, EG2280 and EG2288 antenna frames. For multiple antennae
installation,synchronizationisnecessary.Table1showsthedetectioninthegeneralenvironment:
Table 1
Model
Tag/Label Detection
EG2266/EG2288/EG2268
4x4cm label Average 0.75m, Max 1m(perside)
UFOtag(Q≥220)
(15767,Ø0.55mm)
Average 1m, Max 1.3m(perside)
When positioning antennae, take note of high power equipment such as air‐conditioning, freezer, soldering
machine, etc. and data line such as power line, communication cable, CCTV cable, etc. as this would cause
interferencetosystems.Itisbesttokeepadistanceof0.6mapart.Westronglysuggesttesting
thesystematthe
desiredsitewithoutsecuringthenutsandboltsbeforepermanentlyfixingintoposition.Oftenrepositioningthe
systembyafewcmmayresolveinterference.
RFswept willinterfereRF transceiversystems ifplacedwithin10mfromRFtransceiver.Ifthereis interference,
thedetectionofRFtransceiver
willreduceby20~30%.
Installation
Multipleantennae
Tomaximizedetectiondistanceandminimizeinterferencebetweensystems,werecommendsynchronizingeach
antennabyinterconnectingthem.Herebelowisadiagramexplainingtheinterconnectingofsystemsatmultiple
installations: