User's Manual

01
01. EP500Pro Introduction
1.1. Introduction
BLUETTI is proud to take the energy storage world by storm with the release of
rolling transport wheels, the EP500Pro was not designed to be a large solar
battery mounted on the wall or in the garage. The BLUETTI EP500Pro was not
can easily be moved to the desired location when necessary, but also a power
backup system that ensures emergency power when a power outage occurs.
which combines digital and analog signals perfectly to manage and control the MPPT
module, the AC Inverter module (Bidirectional topology, supporting AC reverse fast
EP500Pro integrates a solar charge controller, AC charge controller, AC inverter,
lithium battery, and battery management system into one, converts clean and
environmentally friendly solar energy and grid electricity into clean power sent to
all of your home appliances.
EP500Pro Power Station system is suitable for areas with energy shortage or
unstable power, and also for the power supply or disaster emergency in areas
without stable power supply such as isolated islands and borders.
02
1.2. Abbreviation
BMS: Battery Management System
MPPT: Max. Power Point Tracking
SOC: State of Charge
UPS: Uninterruptible Power Supply
AC: Alternating Current
DC: Direct Current
PV: Solar Panel(s) Charging(Photovoltaic)
Grid: Home Power Supplied by Utility
T500: 500W additional charger
DOD: Depth of Discharge
automatically turned off if the load is less than 30W over a span of 4 hours.
02. General Safety Instructions
Please read this manual before operating.
involves connecting the wires of critical equipment from your main electrical
box to the BLUETTI Sub Panel (Optional Purchase).
DO NOT place EP500Pro near heat sources. It is prohibited to place and operate
DO NOT attempt to replace the internal battery or any other components of
serviceable components in the package.
DO NOT operate in wet conditions. If EP500Pro becomes wet, please let the
unit dry completely before using.
Please ensure proper ventilation while in use and do not obstruct fan openings.
Inadequate ventilation may cause permanent damage to the equipment.
DO NOT stack anything on top of the power station either in storage or while
in use.
DO NOT move the unit while operating as vibrations and impacts may lead to
poor connectivity to hardware inside.
03
Warning:
DO NOT insert foreign objects into any ports of EP500Pro (both AC & DC &
ventilation holes). EP500Pro generates the same potentially lethal AC power
as a household wall outlet. Please use EP500Pro carefully and keep children
away from it.
For safety purposes, please use only the original charger and cables designed
equipment and may render your warranty, invalid.
2.1. Installation (for grid-tie system)
Before touching any conductor surface or terminal, measure the voltage of
After the equipment is installed, empty packaging materials such as cartons,
foam, plastic, cable ties, etc. should be removed from the equipment area.
Except for those who operate the equipment, please keep others away from
the equipment.
The handling of any tools being used needs to be insulated and protected
from shock, or use insulated tools.
holes that have been routed and use the cover of the cabinet.
It is strictly forbidden to alter, damage or obscure the logo and nameplate on
the equipment.
When installing the device, please use the appropriate tools to tighten any
screws.
Live operation is strictly prohibited during installation.
stable objects, such as walls or possibly mounting brackets if needed.
It is prohibited to clean any electrical components inside and outside the
cabinet with water.
Do not change or modify the structure, installation sequence, etc. of the
equipment without prior authorization.
2.1.1. Personal Safety
The personnel responsible for the installation and maintenance of the equipment
must first undergo rigorous training to understand various safety precautions
04
and grasp the correct method of operation.
Trained personnel: personnel who have undergone corresponding technical
training and have the necessary experience to be aware of the danger that may
be brought to him during the operation, and can take measures to reduce the
danger to himself or other personnel to at the lowest limit.
The replacement of equipment or parts (including software) must be done by
professionals or authorized personnel.
2.1.2. Personnel Requirements
The personnel responsible for the installation and maintenance of the
precautions and grasp the correct method of operation.
Trained personnel: personnel who have undergone corresponding technical
training and have the necessary experience to be aware of the danger that
may be brought to him during the operation, and can take measures to
reduce the danger to himself or other personnel to at the lowest limit.
The replacement of equipment or parts must be done by professionals or
authorized personnel.
2.1.3. Anti-static requirements
components directly with your hands.
2.1.4. Drilling
The following safety precautions are to be considered when drilling holes on the
wall or into the ground:
It is strictly forbidden to drill holes into the equipment. Drilling will alter and
damage the electromagnetic shielding performance of the equipment, internal
components, and cables. The risk of metal shavings entering the device can
cause short circuits on the circuit board.
Wear goggles and protective gloves when drilling holes.
The equipment should be shielded and protected during the drilling process
to prevent debris from falling into the equipment. After drilling, any debris
which may have landed on the equipment should be removed and cleaned.