User's Manual

M590 GPRS Module Hardware User Guide
Copyright © Neoway Technology Co., Ltd
26
2 26 dBm ±3dBm
3 24 dBm ±3dBm
4 22 dBm ±3dBm
5 20 dBm ±3dBm
6 18 dBm ±3dBm
7 16 dBm ±3dBm
8 14 dBm ±3dBm
9 12 dBm ±3dBm
10 10 dBm ±4Bm
11 8 dBm ±4Bm
12 6 dBm ±4Bm
13 4 dBm ±4dBm
14 2 dBm ±5dBm
15 0 dBm ±5 dBm
5.2.2 Receiving Sensitivity
Band Typical
GSM800&EGSM900 <-107 dBm
DCS1800&PCS1900 <-107 dBm
The data in the above tables is obtained by connecting the module to RF test instrument (e.g.
CMU200, CWM500, or Agilent8960) in lab tests. It is for reference only.