User's Manual

M590 GPRS Module Hardware User Guide
Copyright © Neoway Technology Co., Ltd
22
4 Electric Features and Reliability
4.1 Electric Feature
Table 4-1 Electric feature of the module
Parameter Minimum Value Typical Value Maximum Value
VBAT
Vin 3.5V 3.9V 4.3V
Iin / / 2A
VDD_EXT
Vout
/ 2.8V /
Iout / / 50mA
DIO
Vout
2.3V 2.8V 3.1V
Iout / / 4mA
Vin -0.3V 0V 0.6V
Iin / / 22.5uA
If the voltage is too low, the module might fail to start. If the voltage is too high or there is a voltage burst
during the startup, the module might be damaged permanently.
If you use LDO or DC-DC to supply power for the module, ensure that it output at least 2 A current.
4.2 Temperature
Table 4-2 Temperature Feature
Module Status Minimum Value Typical Value Maximum Value
Working
-40
25
85
Storage
-45
90
If the module works in temperature exceeding the thresholds, its RF performance (e.g. frequency
deviation or phase deviation) might be worse but it can still work properly.