User's Manual
8
basic setup command lamp module is determined by the parameters in the
adjustable brightness levels.
Functions: basic Settings
Parameter number: 2
Specifications: 1 byte
The available Settings: 0, 1-99 or 255
0 - closed, alarm cancel or shut down power supply equipment
1-99 or 99 - open (binary switch equipment)
Light and shade levels (multilevel switch
equipment)
The default Settings: 99
The battery check command
Users can also send BATTERY_GET command query to probe the battery status
of overflowing. Once the water detector receives the command, it will
reply BATTERY_REPORT command. If water detectors send BATTERY_LEVEL =
0 XFF command to Z - Wave master equipment, said water detector battery
die, otherwise BATTERY_LEVEL value range of 0% to 100%。
Wake up the command class
The water detector will maintain in the sleep state most of the time,
reduce the water detector power consumption, extend battery life.
The smallest wake up interval of 120 s;
16777215 s largest wake up of time (about 194 days);
Allows each awaken the interval between the interval of 1 second, like
120121121...
The command class
The sensor (water detector) support command class, as follows:
* COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
* COMMAND_CLASS_VERSION (V2)
* COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
* COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
* COMMAND_CLASS_POWERLEVEL (V1)
* COMMAND_CLASS_BATTERY(V1)
* COMMAND_CLASS_ASSOCIATION(V2)