User's Manual

6
Warm prompt
progr near the easy leakage of water, water will overflow detector probe head
should be on the ground water easy to leak.
Avoid install the .lampblack, such as water vapor directly smoked the place
avoid installed in the enclosure, such as alarm sound is not easy to place.
avoid install where water immersion.
please will overflow water detectors installed on the host network coverage range
The LED display status
1. When the water detector is triggered, the LED flashing red light 5
times.
2. Water detector just equipped with batteries, LED lights flashing red
light 5 times.
3. When the water detector is triggered, keep normally on LED lights.
4. The normal state, the state of LED lights to keep out
Equipment linkage
When spilled water detector is triggered, all of the equipment by its linkage will receive relevant
reports. Spilled water detector by Z - wave main control device can control the Z_wave other
devices within the network, such as linkage socket, alarm equipment, dimmer, and so on.
Water detector support two sets of linkage:
The first set of linkage can be allocated equipment state - when spilled water detector is
triggered, based Settings command to be sent the linkage of the linkage device.
A second group of linkage in Z - wave shown on the main control device or alarm host water
detector current working condition.
Note: the water detector in linkage with other devices, they are direct communication through Z
- wave network, alarm host or Z - wave master equipment was not involved.
Restore the factory Settings
Restore the factory Settings will be deleted and Z Z - Wave network - Wave master all
information relating to the sensors in the device, and restore the sensor to the factory default
Settings.
1. Open water detector host.
2. Ensure the sensor power supply.
3. Long press to code button for 10 seconds.
4. Loosen the button.