User's Manual

Current Load and Energy Consumption
This Plug provides line voltage, current load, power consumption and energy
consumption measuring. These measurement results are sent to Z-Wave Controller or
Z-Wave Gateway.
Voltage – The Supply Power Voltage For Plug.
Current – The Current for the Electric Device Connect to Plug Consumption.
Power – Power Consumed by an Electric Device in an instant, unit: Watt (W).
Energy – Energy Consumed by an Electric Device through a Time Period. Most
commonly measured in Kilowatt-hours (kWh). One kilowatt-hour is Equal to One
Kilowatt of Power Consumed over a Period of One Hour, 1kWh = 1000Wh.
Advanced Configuration
1.Send Meter Report Enable
This parameter defines Disable/Enable meter report measure data to controller.
Function: Meter Report Enable
Parameter Number: 1.
Parameter Size: 1 Byte
Available Settings0,1.
0 – Disable Report,
1 - Enable Report
Default Setting: 1.
2. Meter Report Interval
This parameter defines interval time (in seconds) that Meter report data to main
controller.
Function: set the upper current threshold.
Parameter Number: 2.
Parameter Size: 2 Byte
Available Settings 1 65535(s).
Default Setting: 300(s)
3. Configure maximum over-load current
This parameter defines maximum current the plug can provide to load that be
connected to plug.
If the current consumed by load greater than maximum current, the plug will cut off
power.
Function: set the upper current threshold.
Parameter Number: 3.
Parameter Size: 1 Byte