User's Manual
activated. If the ambient illumination level falls below this value and a person moves
across or within the detected area , PIR detector will send a Z-Wave ON command(i.e.
BASIC_SET value = parameter 3#) to an associated device and activate it.
Function: Lux Level Set
Parameter Number: 5
Parameter Size: 2 Byte
Available Settings: 0 - 1000(Lux)
Default Setting: 100(Lux)
6. Re-trigger Interval Setting
This Parameter can be used to adjust the interval of being re-triggered after the PIR
detector has been triggered. No report will be sent during this interval if a movement
is presented. This Parameter value must be less than Parameter 2#.
Function: Re-trigger Interval Setting.
Parameter Number : 6
Parameter Size:1 Byte
Available Settings:5 ~ 120(s)
Default Setting:10
7. Light Sensor Polling Interval
This Parameter can be set the light sensor measure ambient illumination level interval
time.
NOTE: This Value Must Be less than Wakeup Interval Time.
Function:Light Sensor Polling Interval
Parameter Number:7
Parameter Size:2 Byte
Available Settings:60 - 36000(second)
Default Setting:600(s)
8. Reserved
9. Ambient illumination Lux Level Report
This parameter defines by how much Lux Level must change, in lux, to be reported to
the main controller.
Function:Lux Level Report
Parameter Number:9
Parameter Size:2 Byte
Available Settings:0 - 1000(Lux)
Default Setting: 100(Lux)
Command Classes