User's Manual

activated. If the ambient illumination level falls below this value and a person moves
across or within the detected area , PIR detector will send a Z-Wave ON command(i.e.
BASIC_SET value = parameter 3#) to an associated device and activate it.
Function: Lux Level Set
Parameter Number: 5
Parameter Size: 2 Byte
Available Settings: 0 - 1000(Lux)
Default Setting: 100(Lux)
6. Re-trigger Interval Setting
This Parameter can be used to adjust the interval of being re-triggered after the PIR
detector has been triggered. No report will be sent during this interval if a movement
is presented. This Parameter value must be less than Parameter 2#.
Function: Re-trigger Interval Setting.
Parameter Number : 6
Parameter Size1 Byte
Available Settings5 ~ 120(s)
Default Setting10
7. Light Sensor Polling Interval
This Parameter can be set the light sensor measure ambient illumination level interval
time.
NOTE: This Value Must Be less than Wakeup Interval Time.
FunctionLight Sensor Polling Interval
Parameter Number7
Parameter Size2 Byte
Available Settings60 - 36000(second)
Default Setting600(s)
8. Reserved
9. Ambient illumination Lux Level Report
This parameter defines by how much Lux Level must change, in lux, to be reported to
the main controller.
FunctionLux Level Report
Parameter Number9
Parameter Size2 Byte
Available Settings0 - 1000(Lux)
Default Setting: 100(Lux)