Product Info
Table Of Contents
TEL: +86-755-2103 8160 EMAIL: sales@minewtech.com URL: www.minewtech.com 8
E8 TagBeacon
MiniBeaconPlus Configuration Instruction
Frame Type
Adv. Interval (ms)
RSSI@1m (dBm)
RSSI@0m (dBm)
Radio Power (dBm)
iBeacon
900
-59
---
0
UID
2000
---
-24
0
URL
2000
---
-24
0
TLM
4000
---
-24
0
Info
4000
---
-24
-8
Adv. Interval: Advertising interval;
RSSI: Measured power, it’s used for the calibration and calculating relative distance.
Radio Power: Transmission power;
2.5 Trigger:
The trigger function will be activated and configured ONLY when the beacon device has a push
button or loaded the sensor such accelerometer, temperature, light and others.
2.5.1 Trigger Settings
1. Select the SLOT1 (iBeacon) and Enable “Trigger”, see image 13 & 14;
13 14
2. Click “Button double tap” and then selcet “Button double tap” as image 14;
3. Enable “Always adverstise” as image 13;
4. Choose the “Adv interval” and “Radio Txpower” as image 13 (under “Always advertise);
5. Click “SAVE” button at the top corner of screen, all new settings take effect immediately;
After completed above step 1 to 5, the beacon device will advertise iBeacon at SLOT1 with
pre-settting interval and transmission power only when dobule-clicking the push button.
2.5.2 For Beacon (accelerometer), each SLOT can be triggered by the accelerometer. For example: if
the SLOT1 has been configured the Trigger, E8 starts to advertising SLOT1 ONLY WHEN an
object is moving or after an object has fallen.