User's Manual
Table Of Contents
- 1 Safety
- 2 General Product Description
- 3 Getting Started
- 3.1 Unpacking and Checking
- 3.2 Environmental Requirements
- 3.3 Connecting the ECG Leadwire
- 3.4 Installing the Batteries
- 3.5 Powering On the Unit
- 3.6 Understanding Touch Gestures
- 3.7 Basic Operations
- 3.7.1 Understanding the Screen Display Orientation
- 3.7.2 Browsing the Screen Display
- 3.7.3 Switching the Screen Display Orientation
- 3.7.4 Flipping the Landscape Display
- 3.7.5 Displaying the Quick Keys Area
- 3.7.6 Entering the Main Menu
- 3.7.7 Turning the Display Off
- 3.7.8 Turning the Display On
- 3.7.9 Unlocking the Screen
- 3.7.10 Acknowledging the Nurse Call
- 3.8 Using the Pouch
- 4 User Configurations
- 5 Patient Management
- 6 Alarms
- 7 Monitoring ECG
- 7.1 Introduction
- 7.2 Safety
- 7.3 Preparation for Monitoring ECG
- 7.4 Changing the ECG Settings
- 7.5 Understanding the ECG Display
- 8 Monitoring SpO2 (Optional)
- 9 Monitoring with the TD60 at the CS
- 9.1 Introduction
- 9.2 Physiological Alarms
- 9.3 ECG Monitoring
- 9.4 QT Monitoring
- 9.5 ST Monitoring
- 9.6 Arrhythmia Monitoring
- 9.7 SpO2 Monitoring
- 10 Configuring the TD60
- 10.1 Introduction
- 10.2 Maintenance Menu
- 10.2.1 Entering the Maintenance menu
- 10.2.2 Configuring the General Menu
- 10.2.3 Configuring the Alarms Menu
- 10.2.4 Quick Keys Menu
- 10.2.5 Configuring the Defaults Menu
- 10.2.6 Transferring a Configuration
- 10.2.7 Screen Lock Menu
- 10.2.8 Changing the Passwords
- 10.2.9 Changing the Device Name
- 10.2.10 Demo Mode
- 10.2.11 Service Menu
- 11 Battery
- 12 Troubleshooting
- 13 Cleaning and Disinfecting
- 14 Maintenance
- 15 Accessories
- A Product Specifications
- B EMC
- D Symbols and Abbreviations
- E Anomaly
Wireless Specification Product Specifications
A - 8 TMS60 Operator’s Manual
A.6.3 Function Specification
WARNING
• Do perform all network functions of data communication within an
enclosed network.
Data integrity
Code error ≤ 1%
Data latency
Total delay of data transmission from the transmitter to the CS:
≤ 3 seconds
Priority
All communication data type have the same priority.
Transmission distance
Distinct vision distance between the transmitter and the
receiver antenna is greater than or equal to 50 m.
Receiver capacity
16 beds
System capacity
32 beds
Dynamic networking stability
The wireless functions of the test transmitter are normal while
the transmitter is moving at the rate of no more than 3.75 m/s
within the wireless transmission distance.
Resistance to wireless interference
When the distance between the wireless device at the
frequency of 2.4 GHz (including cellular mobile communication
networks, microwave ovens, cordless phones, and other
devices) and the receiver antenna is one meter, and the receiver
antenna exists a WMTS interference at the same frequency of -
118 dBm, the wireless functions are normal.
Communication interruption alarm
After the communication between the transmitter and the
receiver is interrupted, the CS displays the alarm information
within five seconds.
Signal strength detection
RSSI detection scope: -110 dBm to -80 dBm