Thermal Image Scope User Manual
Thermal Image Scope User Manual Legal Information About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons.
Thermal Image Scope User Manual LATTER PREVAILS.
Thermal Image Scope User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules.
Thermal Image Scope User Manual Wi-Fi 2.4 GHz (2.4 GHz to 2.4835 GHz): 20 dBm Use the power adapter provided by a qualified manufacturer. Refer to the product specification for detailed power requirements. Use the battery provided by a qualified manufacturer. Refer to the product specification for detailed battery requirements. Directive 2012/19/EU (WEEE Directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union.
Thermal Image Scope User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Danger Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury. Caution Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.
Thermal Image Scope User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. Laws and Regulations ● Use of the product must be in strict compliance with the local electrical safety regulations. Transportation ● Keep the device in original or similar packaging while transporting it. ● Keep all wrappers after unpacking them for future use.
Thermal Image Scope User Manual ● Do not leave the battery in an extremely high temperature surrounding environment, which may result in an explosion or the leakage of flammable liquid or gas. ● Do not subject the battery to extremely low air pressure, which may result in an explosion or the leakage of flammable liquid or gas. Maintenance ● If the product does not work properly, please contact your dealer or the nearest service center.
Thermal Image Scope User Manual Table of Contents Chapter 1 Overview...................................................................................................................... 1 1.1 Device Description .............................................................................................................. 1 1.2 Main Function ..................................................................................................................... 1 1.3 Appearance ................................
Thermal Image Scope User Manual Chapter 5 Measure Distance ...................................................................................................... 22 Chapter 6 Picture and Video ....................................................................................................... 23 6.1 Capture Picture ................................................................................................................. 23 6.2 Record Video ..........................................................
Thermal Image Scope User Manual Chapter 1 Overview 1.1 Device Description The thermal image scope is equipped with high-sensitivity IR detector and advanced thermal imaging technology, which gets clear view in poor visibility or dark environment. It helps to view the target and measure the distance. It can aim at the moving target and meet the outdoor condition. The device can be widely used in searching and rescuing, hiking, travel, etc. 1.
Thermal Image Scope User Manual Figure 1-1 Components and Interfaces Table 1-1 Description of Components and Interfaces No. Component Function 1 Lens Cover Protect the lens.
Thermal Image Scope User Manual 2 Focus Ring Adjust the focal length. 3 Expansion Rail Hole Install the expansion rail. 4 Battery Compartment Install the device battery in it. 5 Eyepiece View the target. 6 Diopter Adjustment Ring Adjust the dioptric correction. 7 Data Exchange Interface Charge the device and transmit data. 8&9 Rail Interface Install the rail. 1.3.2 Button Figure 1-2 Buttons on Device Table 1-2 Description of Buttons No.
Thermal Image Scope User Manual 4 Down ● Press: Select parameters/capture ● Hold: Start/stop recording Note Combination Button: ● + : Enable/disable crosshair ● + : Enable/disable distance measurement 4
Thermal Image Scope User Manual Chapter 2 Preparation 2.1 Cable Connection Connect the device and power adaptor with a type-C cable to charge the device. Alternatively, connect the device and PC to export files. Figure 2-1 Cable Connection 2.2 Install Battery Insert the batteries into the battery compartment. Before You Start ● The device supports 3.0 V or 3.7 V battery. ● Select the correct battery voltage in the device menu after you install the battery, or it may cause device exception.
Thermal Image Scope User Manual Figure 2-2 Loosen the Cover 2. Insert batteries into the battery compartment with the positive mark inward. Figure 2-3 Install the Battery 3. Turn the battery cover clockwise to tighten it.
Thermal Image Scope User Manual Take the batteries away if the device is not used for a long time. 2.3 Install Rail Before You Start ● Turn off the device first. ● Use the Non-dust cloth to clean the device base and the rail. Steps 1. Install the device to the rail as the arrow shows. 2. Insert the screws, and tighten them. Figure 2-5 Install Rail and Tighten Screws 3. Tighten the knobs to secure the device. Figure 2-6 Tighten Knobs 4. Insert and tighten the screws to fix the expansion rail.
Thermal Image Scope User Manual Figure 2-7 Install Expansion Rail and Tighten Screws 2.4 Power On/Off Power On When the battery is sufficiently charged, press to power on the device. Power Off When the device is turned on, hold for 2 seconds to power off the device. Note ● See the battery icon for the electricity quantity. means the battery is fully charged or the device is charged by external power, and means that the battery is low. ● When the low power note shows, charge the battery.
Thermal Image Scope User Manual 2.5 Interface Description When the device is turned on, you can see the live view interface. Figure 2-8 Live View Interface 2.5.1 Status Bar Settings You can choose whether to display the status bar in the live view interface in this function. Steps 1. Hold to go to the menu. 2. Press or to select setting interface. 3. In the status bar Interface, press 4. Hold (Status Bar Settings), and press or to enter status bar to select Display or Auto-Hide.
Thermal Image Scope User Manual Figure 2-9 Shortcut Menu Interface 2.5.3 Menu Description When the device is turned on, hold to show the menu. In the menu, you can press to select functions, press function, and hold or to save settings and exit.
Thermal Image Scope User Manual Chapter 3 Image Settings 3.1 Adjust Diopter Steps 1. Power on the device. 2. Open the lens cover. 3. Hold the device and make sure the eyepiece covers your eye. 4. Adjust the focus ring until the OSD text or image is clear. Figure 3-1 Adjust Diopter Note When adjusting diopter, DO NOT touch the surface of lens to avoid smearing the lens. 3.2 Adjust Focus Steps 1. Power on the device. 2. Hold the device and make sure the eyepiece covers your eye. 3.
Thermal Image Scope User Manual Figure 3-2 Adjust Focus Note When focusing, do not touch the surface of lens to avoid smearing the lens. 3.3 Adjust Brightness In white hot mode, the higher the value of brightness is, the brighter the image is. The image effect in white hot mode is showed as picture below and effect in black hot mode is opposite. Steps 1. Press to go to the shortcut menu. 2. Press or to select 3. Press or to adjust brightness. 4. Hold to save settings and exit.
Thermal Image Scope User Manual 2. Press or to select (Contrast) and press 3. Press or to adjust image contrast. 4. Hold to save settings and exit. to enter the setting interface. 3.5 Select Scene You can select proper scene mode according to actual using scene to improve the display effect. Steps 1. Press to go to the shortcut menu. 2. Press or to select Scene Mode and press 3. Press or to switch scene mode. – refers to city mode. – – – refers to jungle mode. refers to stone mode.
Thermal Image Scope User Manual Figure 3-4 White Hot Mode Black Hot The hot part is black-colored in view. The higher the temperature is, the darker the color is. Figure 3-5 Black Hot Mode Red Hot The hot part is red-colored in view. The higher the temperature is, the redder the color is.
Thermal Image Scope User Manual Figure 3-6 Red Hot Mode IronBow If the color is close to yellow, the temperature is high. If the color is close to purple, the temperature is low. Figure 3-7 IronBow Mode Color One From high temperature to low temperature, the image is colored in from red, yellow, green, blue to purple. Figure 3-8 Color One Mode Color Two From high temperature to low temperature, the image is colored in from white, yellow, red, pink to purple.
Thermal Image Scope User Manual Figure 3-9 Color Two Mode 3.7 Correct Defective Pixel The device can correct the defective pixels on the screen. Steps 1. Hold to go to the menu. 2. Press or to select (DPC), and press to enter DPC setting interface. 3. In the DPC Interface, press to select Axis, and press to switch the moving direction of the cursor. 4. Press or to move the cursor until it reaches the defective pixel, and press to select Axis to N. 5.
Thermal Image Scope User Manual Figure 3-10 DPC ● DPC is only supported in the white hot mode. 3.8 Flat Field Correction This function can correct non-uniformity of display. Steps 1. Hold to go to the menu. 2. Press or to select 3. Press or to switch the FFC mode. (FFC), and press to confirm. – Manual FFC: In the live view interface, hold to correct the non-uniformity of display. – Auto FFC: The device performs FFC automatically according to the set schedule when the device is turned on.
Thermal Image Scope User Manual Note ● When crosshair is enabled, the PIP view is the detail of crosshair. When crosshair is not enabled, the PIP view is the detail of central part. ● If digital zoom is enabled, the PIP view also zooms. If the digital zoom ratio reaches 16, the PIP does not zoom. 3.10 Adjust Digital Zoom You can zoom the image by using this function. Press in the live view interface, the live view switches between 1×, 2×, 4×, 8×, and 16×. 3.11 Synchronize Time Steps 1.
Thermal Image Scope User Manual Chapter 4 Crosshair Settings 4.1 Select Crosshair Memory If different users use the same device, the users can configure and save the crosshair settings in their respective crosshair memory group. Before You Start Press and to enable crosshair in the live view interface. Steps Steps 1. Hold to go to the menu. 2. Press or interface. 3. Press or 4. Hold to select (Crosshair Memory), and press to enter the setting to switch the crosshair memory group from A to E.
Thermal Image Scope User Manual Figure 6-1 Crosshair Settings 3. Set crosshair type. 1) In the crosshair setting interface, press or to select Crosshair Type. 2) Press to select crosshair type. 7 types of crosshairs can be selected. 4. Set the crosshair color. 1) In the crosshair setting interface, press or to select Color. 2) Press to switch the color of the crosshair. White, Green, Red, Black, Yellow, and Purple are selectable. 5. Set the crosshair position.
Thermal Image Scope User Manual 7. Hold to exit the interface according to the prompt. – OK: Save the parameters and exit. – CANCEL: Exit and not save the parameters. Note ● There are 7 crosshairs can be configured in a crosshair memory group. ● If the PIP function is enabled, the aimed target can be magnified on the interface. ● If you need to reset crosshair, select One-Touch Clear to restore the current crosshair parameters to default.
Thermal Image Scope User Manual Chapter 5 Measure Distance The device can measure the distance between the target and the observation position. Before You Start When measuring the distance, keep the hand and the position steady. Otherwise, the accuracy may be affected. Steps 1. Press and 2. Press to enter target setting interface to set the parameters for the target. 1) Press and press to enter the distance measurement interface.
Thermal Image Scope User Manual Chapter 6 Picture and Video You can manually record video or capture picture in the live view interface. 6.1 Capture Picture In the live view interface, press to capture picture Note When capturing succeeds, the image freezes for 1 second and a prompt shows on the display. For exporting captured pictures, refer to Export Files. 6.2 Record Video Steps 1. In the live view interface, hold to start recording.
Thermal Image Scope User Manual 6.3 Export Files This function is used to export recorded videos and captured pictures. Before You Start ● Turn off hotspot function. ● Turn on the device after connecting it to your PC, and keep the device on for 10 to 15 seconds before other operations. ● Remove batteries from the device before connecting to your PC, or it may cause device damage. Steps 1. Connect the device and PC with cable. Note Make sure the device is turned on when connecting the cable. 2.
Thermal Image Scope User Manual Chapter 7 Network Connection Steps 1. Hold to go to the menu. 2. Press or to select (Wi-Fi), and press to enter the Wi-Fi setting interface. 3. Select Yes to enable Wi-Fi. 4. Turn on the WLAN of your phone and connect to the hotspot. ● WLAN Name: Wlan-IPTS Serial No. ● WLAN Password: Serial No. Note Refer to View Device Information to view the Serial No.
Thermal Image Scope User Manual Chapter 8 Language Settings You can select the device language in this function. Steps 1. Hold to go to the menu. 2. Press or to select (Setting), and press 3. Press or to select (Language) to enter the configuration interface. 4. Press or to select the language as required. 5. Hold to save settings and exit. 26 to enter the setting interface.
Thermal Image Scope User Manual Chapter 9 Video Output The video output is used to view the device image on the display unit for details. Before You Start Connect the device to the display unit via CVBS interface of the aviation plug. Steps 1. Hold to go to the menu. 2. Press or to select (Setting), and press 3. Press or to select (Video Output) to enter the configuration interface. 4. Press or to select ON to enable CVBS. 5. Hold to enter the setting interface. to save settings and exit.
Thermal Image Scope User Manual Chapter 10 Maintenance This part introduces the operation of checking device information, upgrading device, restoring to defaults, etc. 10.1 View Device Information Steps 1. Hold to go to the menu. 2. Press or to select (Setting), and press 3. Press or to select (Version), and press 4. Hold to enter the setting interface. to view the device information. to exit. 10.
Thermal Image Scope User Manual Steps 1. Connect the device to your PC with cable, and then turn on the device. 2. Open the detected disk, copy the upgrade file and paste it to the root directory of the device. 3. Hold to reboot the device, and the device upgrades automatically. The upgrading process will be displayed in the main interface. Note During the upgrade, make sure the device is connected to your PC. Otherwise, it may cause unnecessary upgrade failure, firmware damage, etc. 4.
UDN