RTL8822CE RTL8822CU RTL8822CS COB TSSI MP FLOW
©2019 Realtek Semiconductor Corp.
20
3.1.5.3. Tx index calibration flow
Start Calibration
Set
Data Rate = MCS7-B40
Set
Antenna = A
Set
Antenna = B
Set
Above Channels
sequentially
Find the relation between index
and power level.
The found index is
Index_MCS7_B40
If the channel measuring of the
path have not completed.
The channel measuring had been
done. Switch to another path
Read
Thermal
Value
All the path and channel
measuring had been done.
Figure 7: Tx calibration flow
The flow to find each index is shown as below:
Set Index
= InitIndex
Set Packet Tx
Measure Power
(dBm)
Set Index
= Index + (TargetPower - MeasuredPower) * 4
TargetPower - 0.25 < MeasuredPower < TargetPower + 0.25
Start to
Find Index
Yes
No
Find Index
Figure 8: Finding Tx index flow
Init Index : The power value of init index should be closed to target power.