©2019 Realtek Semiconductor Corp.
14
3.1.4. Crystal calibration
Start to Find Index
Set Index =
InitIndex
Set MCS7 40M Tx
Measure Carrier
Frequency (Hz)
Abs. Value of
MeasuredCFOffset < 2ppm
Have Found Index
Set Index = Index + (TargetCFOffset MeasuredCFOsset) / Step
YES
No
Figure 6: Finding Crystal Cap. Index Flow
InitIndex: the default value is 0x40. Index range is 0x0 to 0x7F.
MeasuredCFOffset: Carrier frequency measured by instrument - ideal carrier frequency
target range Abs. Value of 2ppm in 2.4GHz band is about 10KHz(±5KHz).
TargetCFOffset: generally is 0 ppm.
Step: The value will be different from modules dominated by external capacitor beside the crystal,
so it must be able to modify simply in the initial file of test program. By experience, the value
variation is about +2 ~ +3KHz. The value should be checked by hardware RD and be filled in the
setup file of test program. The plus symbol means that the crystal Cap. index and carrier
frequency is positive-dependent (The larger index is relative to major carrier frequency).