User's Manual
- 16 -
Wrong transceiver IP entered on the programming software or the user forgets transceiver IP.
B. Transmission Failure
Check if the frequency configuration between the portable and transceiver is the same and whether their
modes are matched.
5 Parameters
Frequency Range: 136-174MHz
,
400-470MHz
AC: 100-240V@2.5A 50/60 Hz
DC : 10.8-15.6V@15A
DC Insurance: 13.6V15A
AC Insurance: 2.5A 250VAC, 5x20mm
Insurance Type: HRC ceramic, Time lag (T)
Supplied Power: 200W
TX Power: 40W(UHF) / 45W(VHF)
Size: 482.6mm(Length)*450mm(Width)*44mm(Height)