User's Manual

- 13 -
used as server, the local monitor port should be configured and the slave device is connected to
system network through this port. When it is used as slave device, the serve IP(or domain name) and
port should be configured.
Network Time Slot Configuration: both two time slots can be equipped with or without network. In case of
network status, the internet time slot ID should be configured. When the transceiver is networked, it will
determine whether it should transmit data according to network time slot ID. It transmits data when the
ID is different while it does not transmit data if the ID is different.
Indicator Setting: in the networked status, the transceiver will transmit signals regularly according to
indicator settings, so that the portable radios can perform roaming according to signals. The time interval
to activate the transceiver is ranged from 10 seconds to 600 seconds; 30 seconds by default. The
continual time to activate the transceiver is ranged from 200 milliseconds to 7000 milliseconds, 1000
milliseconds by default.
Encryption Setting: encryption is optional. The password is set to be 10 hexadecimal characters, such as:
8A4428331D.
Message Delay Setting: the delay setting is used to prevent network latency. The user can set the delay
time based on the network status. Value range: 60 milliseconds to 960 milliseconds; step value is 60
milliseconds.
Temperature Control
Fan Control Mode: the fan can be turned on constantly or turned on automatically according to power
amplification temperature.
Power Amplification Protection Temperature: when the power amplification temperature exceeds