Room temperature (20~30) is the most suitable working temperature for the battery,
higher or lower working environment can decrease the battery life span
The point that removing the battery when the UMD connects to adapter can increase the
life span of battery is not exactly right. Please keep the battery in the device when it runs
under adapter power because it will not make the battery overcharge. The charge
controlling and circuit protecting technology are adopted by UMD, once the battery is
full,charging will stop.
Please don’t unpack the battery and keep it alone over three months. The automatically
discharging of the battery also can bring to a over discharging to damage battery. Please
make sure to charge and discharge at least one time every three months.(including the
standby battery)
Prepare a standby battery
Please do not draw or plug the adapter frequently. It is the best way to increase the
battery life span
Battery can be charge and discharge about 300 times under the normal working
environment, over charge and over discharge also can decrease the battery life span
Keep the battery under dry and cold environment, the recommended temperature is
10~30, higner temperature can speed up the discharging to decrease the life span
Please reclaim the used batteries, safe disposal as per the waste electrical disposal way
in your area.
Please do not keep the battery near by the fire source or throw it into the fire, It maybe
cause a exploding.
Please do not disassemble or recombine the battery and make the it short circuit.
5-3 Energy Management Model
If you need a more longer utility time, please setup the automatic mode or adjustable mode of
the power save which built in the UMD through control thepower optionsin Windows XP