User's Manual
Title:
AJ102 Data Concentrator Unit User Manual
Ver.
1.4
Page:
15 of 23
6 Security
6.1 Physical Security
The DCU has two seals for the terminal cover, one seal for the RF antenna box. It is impossible to access
the DCU internal part unless physically and transparently destroy the seals and the DCU face or terminal
cover. The DCU records the main cover removal event and terminal cover removal event in both power on
condition and power off condition.
The DCU detects the meter dismantle/removal event.
6.2 Communication Security
The DCU supports state-of-art security for data access and data transportation basing on a role-based
security. Each role has its own access privileges. Here below table lists all the roles, their privileges,
security mechanism:
Role
Client ID
Privileges
Security Mechanism
Public
16
Read limited DCU information, like the DCU serial
number.
No
Read-Only
2
Read DCU
LLS Mechanism id 1
Read-Write
1
Read DCU, configure DCU parameters
HLS Mechanism id 2
6.3 Keys of DCU
The DCU has the following keys for each DLMS HLS client.
No
Type Name
Description
1
Authentication key
Ensure data integrity and authenticity
2
Encryption key
Ensure data confidentiality
3
Master key
Use to change other keys
Each DCU has its own individual keys once out of factory.
All the keys are updatable from central system.
6.4 Communication Security to Meters
DCU follows smart meter’s security policy. All communication to meters are authenticated and encrypted.