Installation Instructions
Table Of Contents
- (Ver.1.0)
- 1. Summary3
- 3. Major function
- 6. Attentions 10
- 10. FCC Caution11
- 1. Summary
- 2. Electrical characteristics and parameters
- 3. Major function
- 3.1 Radar operating range
- 3.2 Sleep detection function
- a. Detection distance: 2.5m (detection distance be
- antenna surface) The
- b. Sleep quality assessment function: awake / ligh
- c. Sleep time recording function: the data output
- duration of sleep quality
- d. In bed function: in / off bed
- 3.2.1 Respiratory detection function
- a. Detection distance: 0.4m≤x≤2.5m (detection dist
- b. precision:≥90%
- 3.2.2 Heart detection function
- a. Distance measurement: 0.4m≤x≤2.5m (detection di
- b. precision:≥95%
- 3.2.3 Existence of detection
- a. Detection distance: 2.5m (detection distance be
- b. precision:≥90%
- 3.2.4 Move detection
- a. Movement trigger
- 4. Radar operation and installation method
- 5. Typical application mode
- 6. Attentions
- 7. Disclaimer
- 8. Copyright description
- 9.Contact information
- 10.FCC Caution:
JR_G6T_AOP_PUB
Tel:0755-86567969 Mail: jhxk@xkgtech.com Address:912 5A Building,ECO-
Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China
Limited by the beam range of the radar antenna, the effective
action distance of the radar normal direction will be reduced.
Millimeter wave frequency band electromagnetic wave has certain
penetration properties for non-metallic substances, which can
penetrate common glass and wood Plate, screens and thin partition
walls can detect moving objects behind the shelter; but for thicker
load-bearing walls, Metal doors, etc., do not penetrate.
4.3 Operating mode of the radar
After the radar module passes the statistical analysis and
processing, the personnel status of the current detection area is
comprehensively evaluated, and the user can directly use the result.
Real-time operation mode
In this mode, the radar module periodically gives the existence
and movement states of personnel in the current radar detection
area. The main states include:
1) Detect there is anyone in the room;
2) Measure people’s Heart rate and respiratory rate;
In this mode, for the accuracy of the environmental state
judgment, the state output logic of the radar module is as follows:
A. Only when the radar equipment detects the status change, it has
the corresponding status output of the radar; otherwise, the radar
remains silent;