Installation Instructions
Table Of Contents
- model:iBabyⅠ
- (Ver.1.0)
- 1. Summary2
- 3. Major function
- 6. Attentions 10
- 10. FCC Caution11
- 1. Summary
- Characteristic:
- 2. Electrical characteristics and parameters
- 3. Major function
- 3.1 Radar operating range
- 3.2 Sleep detection function
- a. Detection distance: 2.5m (detection distance be
- antenna surface) The
- b. Sleep quality assessment function: awake / ligh
- c. Sleep time recording function: the data output
- duration of sleep quality
- d. In bed function: in / off bed
- 3.2.1 Respiratory detection function
- a. Detection distance: 0.4m≤x≤2.5m (detection dist
- b. precision:≥90%
- 3.2.2 Heart detection function
- a. Distance measurement: 0.4m≤x≤2.5m (detection di
- b. precision:≥95%
- 3.2.3 Existence of detection
- a. Detection distance: 2.5m (detection distance be
- b. precision:≥90%
- 3.2.4 Move detection
- a. Movement trigger
- 4. Radar operation and installation method
- 5. Typical application mode
- 6. Attentions
- 7. Disclaimer
- 8. Copyright description
- 9.Contact information
- 10.FCC Caution:
iBabyI - Baby Monitor
Tel:0755-86567969 Mail: jhxk@xkgtech.com Address:912 5A Building,ECO-
Technology Park,Yehai street,Nanshan district,Shenzhen city,Guandong province,China
1) Detect there is anyone in the room;
2) Measure people’s Heart rate and respiratory rate;
In this mode, for the accuracy of the environmental state
judgment, the state output logic of the radar module is as follows:
A. Only when the radar equipment detects the status change, it has
the corresponding status output of the radar; otherwise, the radar
remains silent;
B. The radar switch from unmanned to manned (motion, approach, away)
is a fast switching state, and the switching time is 1s;
C. If the radar switches from manned to unmanned, it needs to be
confirmed many times and the switching time is 1 minute;
D. Radar collects the breathing / heart rate frequency and breathing
/ heart rate signal state during the dynamic and static human body
in real time. The breathing heart rate frequency refresh frequency
is 3s, and the signal state changes and output;
Sleep detection mode
In this mode, the module periodically gives the sleep status and
breathing rate of the personnel in the current radar detection area, and the
main states include
1) Sleep quality assessment: awake, deep sleep, light sleep;
2) Bed-in / off-the-bed judgment;
3) Statistics of respiratory / heart rate frequency
4) In sleep detection mode, the radar module has a specific
safety for the accuracy of sleep-related state judgment Installation
mode and installation height limit;
The radar should be installed at 1m height directly above the head