User's Manual
08
User Servicing Instruction
Maintenance
● Fuse replacement
Note: The product requires a 2.5 A, 125 V fuse.
1. Grasp the plug and remove from the socket or other outlet device. Do not unplug by
pulling the cord.
2. Slide to open the fuse cover on top of the plug towards blades.
3. Remove the fuse carefully by using a small screwdriver to pry it out of the compartment
by its metal ends.
4. Replace only with 2.5 A, 125 V fuse to avoid the risk of fire.
5. Close fuse cover. Slide closed the fuse access cover on top of attachment plug.
6. Risk of fire. Do not replace attachment plug. Contains a safety device (fuse) that should
not be removed. Discard product if the attachment plug is damaged.
● The fan blade cannot be detached. Do not forcibly pry open the part used to fix the blade,
otherwise it cannot be restored.
● The motor is permanently lubricated and requires no oiling.
● Any other servicing not mentioned in this manual should be performed by a professional
repair center.
To achieve the best performance, clean the fan at least once during the operating season or
before storing it when it will not be used for a long period of time.
● Turn the fan off and unplug it from power, then use a soft damp cloth to clean its body,
air inlet, and outlet.
● Do not immerse the fan in water and never allow water to drip into the motor housing.
● Do not risk your safety to detach the fan to clean its blade, otherwise this way damage the
fan or shorten its lifespan.
Cleaning
Step 1 Step 2
Step 3 Step 4