User's Manual
8
5. Rx Antenna Connector
N/F type RF connector.
6. Tx Antenna Connector
N/F type RF connector can be used independently for both Tx and Rx antenna port when
duplexer is installed.
7. AC Power Inlet
Connect the AC power cord properly and switch the power on to enter AC power supply
mode.
8. AC Power Switch
9. DC Power Inlet
In AC power supply mode, DC floating charging feature is available if connected with
back-up battery; When AC power is switched off, it will auto-revert to DC power supply
mode.
Features and Operations
Basic Operations
1. Switch the AC power on: properly connect the AC power cord and then switch the
power on.
2. Turn the repeater on: rotate the Power/Volume Control Knob clockwise until a click
sounds to turn the repeater on, LED glows red.
3. Enter Repeater Mode: turn on the repeater to enter standby mode. Transmitter and
receiver LED glow simultaneously when a valid signal is detected.
4. Adjust the volume: rotate the Power/Volume Control Knob in Repeater Mode. Adjust
the volume to the minimum level when monitoring is not needed.
Time-out-Timer (TOT)
Time-out-Timer is used to prevent one from using the same channel for a long time and to
prevent the transmitter from damage due to continuous transmission. If the transmission
exceeds the preset time (it’s set by your dealer, max. time is 10 minutes), transmission will
be forbidden. Release the [PTT] key and press it again to resume transmitting.