Product Specs
Shenzhen Huasheng Jiahe Electronic Technology Co., Ltd
6
5、Operating parameter maximum rating
6、Charging protection function
FOD
FOD: Electricity after work, go into standby mode and does not
work, static FOD work function, the metal object is placed in the coil is
around 2 mm above, covered half of the coil, and metal content reaches a
certain degree of above, the static FOD triggered, into an error state, the
indicator light flash immediately prompt error
Parameter
Symbol
Rated
Unit
Operating ambient
temperature
Ta
-20 to +40
℃
Storage temperature
Tstg
-30 to +70
℃
Storage humidity
Tstr
< 95%
RH
Working voltage
Vcc
3.4 to 13.4V
V
Supply current
Imax
3
A