Product Specs

Shenzhen Huasheng Jiahe Electronic Technology Co., Ltd
6
5Operating parameter maximum rating
6Charging protection function
FOD
FOD: Electricity after work, go into standby mode and does not
work, static FOD work function, the metal object is placed in the coil is
around 2 mm above, covered half of the coil, and metal content reaches a
certain degree of above, the static FOD triggered, into an error state, the
indicator light flash immediately prompt error
Symbol
Rated
Unit
Ta
-20 to +40
Tstg
-30 to +70
Tstr
< 95%
RH
Vcc
3.4 to 13.4V
V
Imax
3
A