User's Manual

Att 1 2 3 4 5 Att. 1 2 3 4 5 Att. 1 2 3 4 5
0 dB off off off off off 11dB ON ON off ON off 22dB off ON ON off ON
1 dB ON off off off off 12dB off off ON ON off 23dB ON ON ON off ON
2 dB off ON off off off 13dB ON off ON ON off 24dB off off off ON ON
3 dB ON ON off off off 14dB off ON ON ON off 25dB ON off off ON ON
4 dB off off ON off off 15dB ON ON ON ON off 26dB off ON off ON ON
5 dB ON off ON off off 16dB off off off off ON 27dB ON ON off ON ON
6 dB off ON ON off off 17dB ON off off off ON 28dB off off ON ON ON
7 dB ON ON ON off off 18dB off ON off off ON 29dB ON off ON ON ON
8 dB off off off ON off 19dB ON ON off off ON 30dB off ON ON ON ON
9 dB ON off off ON off 20dB off off ON off ON 31dB ON ON ON ON ON
10 dB off ON off ON off 21dB ON off ON off ON
3.3 LEDstatus
1. St a tusanddefinitionofPOWERindicators:
Status Definition
Green
Normal
Off
DC power problem
2. St a tusandDefinitionofALARMindicators;AlarmLEDonlyworksfor
downlinksignals
Status ALARM
Green
It is working in linearity
attention: Input signals may be not enough
Red
There are overloading or self-oscillation, strong input signals,
measures shall be taken
Orange
It is working in linearity
Attention: Please adjust MGC to increase the attenuation value, till you
find the “edge point” (I.E. the Alarm LED shall stay at green color, with
intention of turning Orange), and let the repeater work at this point.
Off
Repeater break down