User's Manual
1 Installation Requirement
Bearing
You can install the product in an unfixed or a wall-mounted way based on your needs. The
wall-mounted way can save a large amount of space.
If the product is installed in an unfixed way, use the designated hanger or holder. If you want
to use a self-made hanger or holder, ensure that the bearing capacity of it is at least four times
of the weight of the product, and the product is installed stably on it.
If the product is installed in a wall-mounted way, the bearing capacity of the surface for
installation must be at least four times of the weight of the product. If the surface for
installation is the wall or the ceiling of a building, the surface must be made of solid bricks,
concrete or other materials with equal intensity. If the product is installed on a surface made
of loose material such as an old brick wall, wood plank wall, solid brick wall, or a metal or
non-metal structure surface, or a surface with a thick decoration layer, take necessary
consolidating measures to ensure that the product is stably installed.
Ventilation
Ventilation
requirements
Distance to the surface for installation (cm)
Nominal power Left and right sides Top Bottom Back
Greater than 100 W 10 20 20 10
If the product is installed inside a wall or a cabinet, in addition to the preceding requirements,
the ventilation area around the bottom, top and two sides must be at least 50% of the sealing
surface to ensure proper ventilation.