User's Manual
Table Of Contents
- NOTICE
- MountingRequirements
- Introduction
- BasicOperation
- AssembleOPSComputer
- Smartbar
- HomePage
- TaskManager
- WhiteBoard
- Gallery
- FileManager
- SystemSettings
- RestoreDefaultSetting
- Browser
- Programs
- SelectSignalChannel
- Menu
- ECOMode
- SerialPortControl
- SpecificationsofPCMode(VGAInput)
- FormatsSupportedbyUSBMode
- MaintenanceTips
- Specifications
5
Mounting Requirements
Bearing
You can choose the potable or wall mounting method according to your needs. Wall mounting can
substantially save the space.
If you choose portable mounting, use the mounting rack or support. If you want to use a self-made mounting
rack, the bearing capacity of the rack should be at last four times of the actual weight of the display. The
bearing capacity of the mounting support must be at least four times of the actual weight of the display to
ensure steadiness of the interactive panel.
When you choose wall mounting, the bearing capacity of the mounting surface must be at least four times of
the weight of the display. When the mounting surface is a wall or ceiling of a building, the wall must be built
with solid bricks, concrete or materials of equal intensity. If you need to mount the display on a loose surface
such as an old brick wall, wood plank wall, solid brick wall, metal or non-metal structure wall, or a wall with
a thick decoration layer, take necessary consolidating measures to ensure that the display is steadily mounted.
Ventilation
Ventilation requirements Distance to the mounting surface (cm)
Nominal power Left and right sides Top Bottom Back
Larger than 100W 10 20 20 10
Note: If the product is mounted inside a wall or a cabinet, in addition to the above-mentioned requirements,
the area of ventilation holes at the bottom, top and two sides must be at least 50% of the sealing surface to
ensure proper ventilation.