User's Manual
Table Of Contents
Alarm temperature range
Set the alarm temperature range in the blending mode, that is, the device will alarm if
the detected temperature is within this range.
Alarm prompt:
The target recognition box displays red, the periphery of screen also flashes red, and
the text prompts "Warning: abnormal temperature"; the buzzer produces 1 long
"beep", and the audio outputs 4 "beeps".
Suspected temperature range
Set the suspected temperature range in the blending mode, that is, the device will
alarm if the detected temperature is within this range.
Alarm prompt: the recognition box displays orange, the buzzer produces 2 short
"beeps", and the audio outputs 2 "beeps".
Normal temperature
The measured target temperature is normal temperature in the range except alarm
and suspected temperature, and choose to take photos of the normal temperature
target automatically or close it.
At normal temperature, the target recognition box on the screen displays green, the
buzzer produces 1 short "beep", and the audio outputs 1 short "beep".
Suspected temperature
In case the measured target temperature is in the suspected temperature range,
choose to take photos of the suspected temperature target automatically or close it.
Alarm temperature
In case the measured target temperature is in the alarm temperature range, choose
to take photos of the alarm temperature target automatically, record a video or close
it.
----------------------------------------------------------------------------------------------------------------
The alarm function is only valid in the blending mode.
16