Specifications

COMMON FAULTS AND TROUBLESHOOTING METHODS
Common error Cause of issue
“ERR2” signal sign blinks on the
digital screen and with alarm.
“ERR1” signal sign blinks on the
digital screen and with alarm.
It’s AC Inverter overload protection. When the
continuous load power of the portable power
station is over 350W, the inverter will automatically
protect and stop the AC inverter output.
It’s AC inverter output short circuit protection.
When a short circuit occurs at the output of the
portable power station AC inverter, the inverter
will automatically protect and stop the AC
inverter output.
When the AC inverter output over-temperature
protection, the portable power station inverter
will automatically protect and stop the AC
inverter output
Problem-solving method
Please do not use overpowered load, and reboot AC button
again.
Please check whether your load is short-circuited, and
remove the load and reboot the AC button again.
Please wait until the temperature drops to room tempera-
ture before rebooting the AC function
“ERR3” signal sign blinks on the
digital screen and with alarm.
14