Specifications
COMMON FAULTS AND TROUBLESHOOTING METHODS
Common error Cause of issue
"Beep" alarm sounds when in use.
When the AC switch is turned on,
the AC110 or 220V indicator is
displayed on the display, but it
will automatically turn off soon.
The AC output port stops output.
If the “ERR” signal sign blink on
the digital screen, please refer to
the next page table.
The FOD lamp is shown on the
display.
Wireless charging output failure protection. There
are metal products in the wireless charging
area.Wireless charging overheat protection.
When the AC starts, the display shows AC11 OV as
the indicator icon. If there is no electrical
appliance connected to the AC within 1 minute, it
means that the electrical equipment is not turned
on. When AC starts, the display shows AC110V as
the indicator light on the icon, and the electric
equipment is also turned on but the power of the
electric equipment.perform automatic overpower
protection. 3. When the battery charge is 20%
lower, the AC cannot output.
When the capacity of the battery is less than 20%,
the alarm prompt will be issued at intervals of
"beep". At this time, you need to pay attention to
save the relevant electrical equipment informa-
tion to avoid automatic shutdown and data loss.
When the capacity of the battery is less than 20%,
the alarm prompt will be issued at intervals of
"beep". At this time, you need to pay attention to
save the relevant electrical equipment informa-
tion to avoid automatic shutdown and data loss.
The display program has the fault with unknown
randomness.
Problem-solving method
Remove the wireless charging product and check the device
for short circuits.Check if there are any belongings in the
wireless charging area, and remove the metal objects to
recover automatically.
1. When the AC output indicator on the display screen is
displayed, if the battery of the powered device is not inserted
within 1 minute, the automatic energy saving mode will be
automatically turned on. If you want to continue to connect
the battery, you need to turn on the AC power output switch
again.
2. The AC output is too high power protection, please
confirm whether the power of the connected equipment is
greater than 300W. if the power exceeds 300w. the electric
equipment will not Work for a long time.
3. Please charge the battery in time for normal use.
Low battery reminder please charge the device n time.
It is the battery mode of working. Please press and hold the
AC power output switch for 3 seconds to exit the UPS mode.
Please press the AC power output switch, and restart the
battery to restore the normal display.
The battery emits a "beep"audible
alarm and the AC icon on the
display keeps flashing.
After unplugging the electrical
equipment, the display remains at
the same power as the load for
more than 30 seconds.
13