Operating Manual

working mode (remote control system) on the mobile terminal through the APP.Set
the temperature controller working mode through the touch screen;
2. The thermostat working mode can be set through the touch screen;
3. Time display and temperature display;
4. Automatic adjustment of room temperature;
5. Memory function of power failure
6. A white backlit square LCD screen.
7. Multiple time modes: 5+2/6+1/7 days, 6 stages per day.
8. Free choice of manual or automatic modes for different purposes.
9. Keyboard locking function to prevent child abuse.
Technical parameters:
1. Operating voltage: ac110-240v, 50/60 HZ
2. Maximum switch current: 16A
3. The internal sensor: NTCB = 3380 10 k @ 25 , the sensor measurement range: 0
to 40 , accuracy: + / 0.1
4.External sensors: NTCB = 3380 = 10 k @ 25 length 3 meters, measuring range:
0-99 , accuracy: + / - 1 , set range: 5-90 (factory setting: overtemperature
protection 50 )
5. A 3-meter external sensor cable is provided
Note:
1. Please read the instruction before use
2. The thermostat can only be used for the purposes specified by the
company.Unauthorized modification and use of parts not sold or recommended by the
company may cause the system to fail or even fail.
3. Avoid using this thermostat in the atmosphere containing carbon dioxide, hydrogen
sulfide or other corrosive gases; otherwise, the relay will be electrocuted.
4. After the whole machine is installed, connect the relevant leads, and the power can be
sent to run under the condition that there is no error.
5. Do not grill the sensor probe with a lighter.
6. Do not apply the maximum rated voltage and current on the relay output contact.