Cell Phone Signal Solutions
2.3 Cable layout and connector assembly
Fix the outdoor antenna after selecting the best position, and adjust height or angles
slightly in order to get the best signal with suitable input power level and calling quality.
(1) Keep the type,specifications, routing direction, and curvature radius of cables in
compliance with the design requirement. Place cables in good order, bend them smoothly
and protect the outer covering against any damage.
(2) Bind cables in good order when laying them on cable racks. When leading cables in or
out of troughs, use a hole opener to open the cable troughs and then install pvc lock nuts
to protect them.
(3) Keep horizontal cables straight and fasten them with a fixing clip every 1 to 1.5
meters.
(4) Bind and fasten vertical cables every two meters to avoid damaging cables or
connectors due to their own weight. Pull back the cables and relay them in shorter
sections if you have difficulty in pulling them. Avoid using a strong force to pull them.
(5) Separate RF cables from power cables. Take proper isolation measures if they are to
be placed on the same cable racks due to the limitation of site conditions.
(6) Correctly fasten all connection parts of the whole system, from the antenna to active
interfaces to passive interfaces, and keep electrical interfaces well contacted. Offer
waterproof treatment to outdoor connection parts.
(7) Take lightning protection measures for the antenna and feeder system in accordance
with the design requirement. Avoid deforming the antenna feeder where grounding clips
are placed, and offer waterproof treatment to the feeder.