Document Name:APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 Lora User Manual Document No.: APN0000236V0.3.1 Product Model UDL07XX Subsystem name and model Module name Doc.#: #: APN0000236_V0.3.
Document Name:APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 Revision History Revision Initiator Reviewed Approved by by Revision Description Issue Date V0.1.1 Fish Yu Initial version Eileen Zhou Johny Wu John Gu 13 May 2022 V0.2.1 Alex Qin Added FCC Warning Information. Eileen Zhou Johny Wu John Gu 15 Jul. 2022 Alex Qin Deleted Footer of “Excelland Confidential, Do Not Copy or Distribute without Permission”. Eileen Zhou Johny Wu John Gu 28 Jul.
Document Name:APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 Contents Chapter 1 Brief Introduction of Product ............................................................................... 5 1.1 General ................................................................................................................... 5 1.2 Features and Benefits ............................................................................................ 5 1.3 Working Principle..............
Document Name:APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 3.3.3 ID ................................................................................................................ 18 3.3.4 working frequency ...................................................................................... 19 3.3.5 Air speed .................................................................................................... 19 3.3.6 Transmitting power .................................
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 Chapter 1 Brief Introduction of Product 1.1 General UDL07XX Lora data transmission terminal is a wireless data transmission terminal based on Lora spread spectrum technology. At the same time using Lora wireless transmission technology for short distance data transmission.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 Stability and Reliability Support hardware and software WDT. RS232/RS485/RS422 port: 15KV ESD protection. Power port: reverse-voltage and over voltage protection. Antenna port: lightning protection(optional). Standard and Convenience Adopt terminal block interface, convenient for industrial application. Support standard RS232 and RS485(or RS422) port that can connect to serial devices directly.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 1.3 Working Principle The principle chart of the Lora is as follows: Lora ANT Lora User interface Power RS232 RS485 IO1 IO2 IO3 IO4 IO5 1.4 Specifications Lora Specification Item Module Content Industrial Lora module The product family supports a wide range of Communication frequency bands around the world (470/780/868/915 Frequency Band MHz) Indoor/Urban Communication F8L10T-N:1km F8L10T-E:2km F8L10T-N:3.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 Bandwidth 6 level adjustable(0.3、0.6、1.0、1.8、3.1、5.5Kbps) TX Power 15.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 Power supply Item Standard Content DC 12V/0.5A Power Power range DC 5~36V Consumption Item Working condition Consumption Sleep 3.1~3.2mA@12 VDC Receive data 13.2~13.4mA@12 VDC Transmit data 60.3~61.2mA@12 VDC Sleep 7.3~7.4mA@5 VDC Receive data 26.1~26.2mA@5 VDC Transmit data 107.3~115.1mA@5 VDC Sleep 3.1~3.3mA@12 VDC Receive data 13.2~13.4mA@12 VDC Transmit data 110-125mA@12 VDC Sleep 7.2~7.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Item Document level: 2 Content Housing Iron, providing IP30 protection Dimensions 91x58.5x22 mm Weight 205g Environmental Limits Item Content Operating -40~+85ºC(-40~+185℉) Temperature Storage -40~+125ºC(-40~+257℉) Temperature Operating 95% ( unfreezing) Humidity Doc.#: #: APN0000236_V0.3.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 Chapter 2 Installation Introduction 2.1 General The Lora must be installed correctly to make it work properly. Warning: Forbid to install the MODEM when powered! 2.2 Encasement List Name Quantity Remark Lora host 1 Lora Antenna 1 Power adapter 1 RS232 data cable 1 optional RS485 data cable 1 optional Manual CD 1 Certification card 1 Maintenance card 1 2.
Document level: 2 APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final 8 22 28 4 Ф3 Ф5 35 25 28 58.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 mA) 12 IO5 ADC, analog input GPIO function (current collection 0 ~ 20 mA) Formulas to calculate collected value of ADC Voltage: (collected value)*3.3*20.16/(4095*12.1) V Current: (collected value)*3.3*1000/(4095*150)(mA) Installation of cable: IP MODEM adopts industrial terminal block interface. The recommendatory cable is 28-16AWG.
Document level: 2 APN0000236_V0.3.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Indicator State Document level: 2 Introduction Light ON Lora is powered on OFF Lora is powered off BLINK Data is communicating OFF No data ON Lora has logged on network OFF Lora hasn’t logged on network Power ACT Online Doc.#: #: APN0000236_V0.3.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 Chapter 3 Configuration 3.1 Configure connection In the Lora digital transmission terminal configuration, the need to pass the factory configuration RS232 serial cable or rs232-485 conversion line Lora data transmission terminal and configured to connect the PC together, is as follows: Figure 3-1 UDL07XX Configuration Connection with PC 3.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 For more details, refer to “AT command manual”. Configure the UDL07XX parameters by configuration software, as shown in Figure 3-2. Figure 3-2 Configuration Interface Column display serial parameters currently open serial port settings in the serial port parameters,please choose the correct value of this configuration, at the same time, open the serial port.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 3.3 Detailed parameters 3.3.1 Serial port configuration It can configure the baud rate, data bit, parity bit and stop bit of the communication serial port. Default: 115200 Baud rate, Attributes 8N1. 3.3.2 Serial port work mode Module serial data work can be divided into "TRNS","AT" and "API". "TRNS": data transmission, when the need to pass through the address configuration, namely the destination address.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 3.3.4 working frequency Module data transmission frequency, different hardware modules can work different frequency bands, roughly divided into low frequency band (525MHz below) and high frequency band (525MHz above) two categories.Typical operating frequency band is 410M ~ 441MHz, 470M ~ 510MHz, 850 ~ 950MHz, etc., 1000KHz for a channel.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 3.3.7 Relay address When the transmission distance between nodes is too far, this parameter is set to the relay node’ ID, and the relay node will help the node forward the data to the final destination node. Default: 1000 3.3.8 Sleep mode When the device is in low power mode, can be set to NONE(not dormant), TIME(timing dormant) and DEEP(deep sleep).
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. FCC Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
APN0000236_V0.3.1_UDL07XX_User Manual_Lora 20220728 Final Document level: 2 the equipment. Doc.#: #: APN0000236_V0.3.