This function code make use of its 1st bit, 2nd bit, 3rd bit, 4
th
bit to set PLC run
mode, PLC rerun mode after interruption, PLC set run time unit,PLC power off
memory time state, detail as follows:
LED 1
st
:
0: no action. PLC run mode ineffective.
1: stop after single circulation. As shown in Fig.6-22,the inverter stops
automatically after finishing a circle,can only start when another run command is
available.
2: keep final value after single circulation. As shown in Fig.6-23,the
inverter keep running according to frequency, direction of final step after finishing
a circle,the inverter won’t stop according to set decelerating time until the stop
command is available.
Fig.6-23 holding mode after PLC single circle