Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 6 Detailed function description
73
resonance frequency of mechanical load.
Inverter set frequency can jump around some frequency point according to mode
shown in Fig. 6-12.
Fig.6-12 jumping frequency and range graph
F2.51 Set run time Range: 065535h 0
F2.52 Run time accumulation Range: 065535h 0
After run accumulative time reach set run time (F2.51)the inverter will output
indicator signalplease refer to F5.10F5.13 function introduction.
F2.52 denotes accumulative run time of the inverter from leaving factory tonow.
F2.53 Reserved
6.4 Closed-loop run function parameter group: F3
Analog feedback control system:
Input pressure specified value through VCI port, send 4~20mA feedback value
of pressure sensor to inverter CCI input portmake up of analog closed-loop
control system by built-in PID adjustoras shown in Fig.6-13.
FWD
COM
GND
VCI
+10V/+5V
GND
CCI
provision 1-3K
M
P
U
V
W
PE
3 phase
380V
QF
EDS1000
send out
pressure sensor
R
S
T
4~20mA
Fig.6-13 built-in PID analog feedback control system graph
Set freq. after adjusted
Jumping range 1
Set freq.
Jumping freq. 1