Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 6 Detailed function description
68
9: reserved
10: reserved
11: reserved
12: reserved
13: VCICCI any nonzero value effectiveVCI preferred
14: reserved
15: RS485+CCI
16: RS485-CCI
17: RS485+VCI
18: RS485-VCI
19: RS485+keypad analog potentiometer
20: RS485- keypad analog potentiometer
21: VCI+ keypad analog potentiometer
22: VCI- keypad analog potentiometer
23: CCI+ keypad analog potentiometer
24: CCI- keypad analog potentiometer
25: reserved
26: reserved
27: reserved
28: reserved
F2.10
main&sub inverter communication
fre
q
.
p
rovision
p
ro
p
ortion
Range: 0500(%) 100(%)
Main&sub inverter communication freq. provision proportionthis parameter
need to be set in sub inverter but not need in main inverter.
F2.11 LED display control 1 Range: 00001111 1111
F2.11 make use of 4 bits of the parameter to set if C-07—C-10 is displayed in
parameter, thereinto 0 indicates not displayed, 1 indicates displayed. Set
parameter of 4 bit is as following figure:
C-07: run time
C-08: accu. run time
C-09: input end status
C-10: output end status
4
th
bit 3
rd
bit 2
nd
bit 1
st
bit