Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 5 Function parameter schedule graph
55
load and over heat.
F9.02
Failure self-renew
interval
0.520.0S 0.1S 5.0S ×
F9.03
Motor overload
protection mode
selection
LED 1
st
b
it: motor overload protection
selection
0: No action
1: Inverter close off output
LED 2
nd
b
it: motor phase loss protection
selection
0Motor phase loss protection enable (this
function is enabled when the output
frequency over 3.00 Hz)
1Close the output phase loss protection
(Not recommended)
1 01 ×
F9.04
Motor overload
protection coefficient
20.0120.0(%) 0.1(%) 100.0(%) ×
F9.05
Overload warning
alarm checkout level
20200(%) 1(%) 130(%)
F9.06
Overload warning
alarmDelay time
0.020.0s 0.1s 5.0s
F9.07
Overvoltage stall
selection
0: ban
1: allow
1 1 ×
F9.08
Overvoltage stall
point
120150(%) 1(%) 130(%)
F9.09
Automatic current
limit level
110200(%) 1(%) 150(%) ×
F9.10
Frequency declining
rate during current
limiting
0.0099.99Hz/s 0.01Hz/s 10.00Hz/s
F9.11
Automatic current
limiting action
selection
0: constant speed ineffective
1: constant speed effective
remark: Acc/Dec always effective
1 0 ×
FdFailure record function parameter group
Function
code
Name Setting range
Min.
unit
Factory
default
Modifi
-cation
Fd.00 Previous one time failure record Previous one time failure record 1 0 *
Fd.01 Previous two time failure record Previous two time failure record 1 0 *
Fd.02 Previous three time failure record Previous three time failure record 1 0 *
Fd.03 Previous four time failure record Previous four time failure record 1 0 *
Fd.04 Previous five time failure record Previous five time failure record 1 0 *
Fd.05 Previous six time failure record Previous six time failure record 1 0 *
Fd.06 Set freq. of previous failure Set freq. of previous failure 0.01Hz 0 *
Fd.07 output freq. at previous failure output freq. of previous failure 0.01Hz 0 *
Fd.08 output current at previous failure output current of previous failure 0.1A 0 *
Fd.09 output voltage at previous failure output voltage of previous failure 1V 0 *
Fd.10
DC bus-bar voltage at previous
failure
DC bus-bar voltage of previous failure 1V 0 *
Fd.11
Load motor speed at previous
failure
Load motor speed of previous failure 1(r/m) 0 *
Fd.12
Module temperature at previous
failure
Module temperature of previous
failure
1 0 *
Fd.13
Input terminal status at previous
failure
Input terminal status of previous
failure
11111111 *