www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 5 Function parameter schedule graph
50
exceptional)
2Running with memory when power off, automotive
running after power on
F4.01 Section 1 setting
000621
LED first bit: frequency setting
0: multisection freq. i (i=1~7)
1: freq. determined by function code F0.00
LED second bit: run direction selection
0: forward run
1: reverse run
2: determined by run command(FWD, REV)
LED third bit: Acc/Dec time selection
0: Acce/Dece time 1
1: Acce/Dece time 2
2: Acce/Dece time 3
3: Acce/Dece time 4
4: Acce/Dece time 5
5: Acce/Dece time 6
6: Acce/Dece time 7
1 000
F4.02 Section 1 run time 06000.0 0.1 10.0
F4.03 Section 2 setting 000621 1 000
F4.04 Section 2 run time 06000.0 0.1 10.0
F4.05 Section 3 setting 000621 1 000
F4.06 Section 3 run time 06000.0 0.1 10.0
F4.07 Section 4 setting 000621 1 000
F4.08 Section 4 run time 06000.0 0.1 10.0
F4.09 Section 5 setting 000621 1 000
F4.10 Section 5 run time 06000.0 0.1 10.0
F4.11 Section 6 setting 000621 1 000
F4.12 Section 6 run time 06000.0 0.1 10.0
F4.13 Section 7 setting 000621 1 000
F4.14 Section 7 run time 06000.0 0.1 10.0
F5Terminal correlative function parameter group
Function
code
Name Set range
Min.
unit
Factory
default
Modifi
-cation
F5.00
Input terminal X1
function selection
0: leave control terminal unused
1: multi-step speed control terminal 1
2: multi-step speed control terminal 2
3: multi-step speed control terminal 3
4: multi-step speed control terminal 4
5: external forward run jog control
6: external reverse run jog control
7: Acce/Dece time selecting terminal 1
8: Acce/Dece time selecting terminal 2
9: Acce/Dece time selecting terminal 3
10: external device failure input
11: external reset input
12: free stop input
13: external stop command
14: stop DC braking input command DB
15: inverter run prohibition
16: frequency increasing control (UP)
17: frequency degression control (DOWN)
18: Acce/Dece prohibited command
19: three-line run control
1 0 ×