Service manual
www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 5 Function parameter schedule graph
45
F2.11
LED display
control 1
0000-1111
first bit: running time
0: not display
1: display
second bit: accumulative time
0: not display
1: display
third bit: input terminal status
0: not display
1: display
kilobit(fourth bit):
output terminal status
0: not display
1: display
1 1111 ○
F2.12
LED display
control 2
0000-1111
first bit: analog input VCI
0: not display
1: display
second bit: analog input YCI
0: not display
1: display
third bit: analog input CCI
0: not display
1: display
kilobit(fourth bit):
exterior pulse input
0: not display
1: display
1 1111 ○
F2.13
Parameter
operation
control
LED 1
st
bit:
0: all parameter allowed to be
modified
1: except this parameter,all
other parameter not
allowed to be modified
2: except F0.01 and this
parameter, all other
parameter not allowed to be
modified
LED 2
nd
bit:
0: no action
1: renew factory default
2: clear history failure record
LED 3
rd
bit( After setting, It will be valid after
pressing MENU key for 5 seconds and entering into
Locc status):
0: lock all buttons
1: all buttons locked except STOP key
2: all buttons locked except
, STOP key
3: all buttons locked except
RUN, STOP key
4: all buttons locked except
SHIFT, STOP key
1 0 ×
F2.14
Communication
configuration
LED first bit: baud rate
selection
0: 1200BPS
1: 2400BPS
2: 4800BPS
3: 9600BPS
1 003 ×