Service manual
www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 4 Run and operation explanation for inverter
40
(6) See about failure parameter under failure status:
Fig.4-11 failure status searching operation example
Description:
1> If press key under failure status the user can see about Fd group
function code parameter, search range Fd.06~Fd.14,LED first display function
code number when the user press key and display parameter digit of this
function code after 1s.
2> When the user see about failure parameter,can press key directly to
switch back to failure alarm display status (E0XX)
(7) keypad key-press locking operation
Under unlocked keypad situation,press key for 5s to lock the keypad.
For detailed operation please refer to 2
nd
bit of F2.13 function code.
(8) keypad key-press unlocking operation
Under locked keypad situation,press key for 5s to unlock the keypad.
1s
1s
1s
1s