Fig. 4-6 waiting status parameter display operating example
Description:
1> All status parameters C-00C-14 can be displayed when the inverter leaves
factory. You can make a change by modifying function code F2.11, F2.12 if
you want to, for detail please refer to F2.11, F2.12function code description.
2> Can press key to switch into constant supervision C-01 display
status directly when the user see about status supervision parameter.
(2) Function code parameter setting
Take function code F2.06 modified from 5.00Hz to 6.00Hz as example.
Boldface in Fig.4-7 shows flickering digit.
Fig.4-7 example for parameter setting and modification
Description: under third-class menu, if the parameter has no blinking digitthis
function code can’t be modifiedpossible reasons are as follows:
1> This function code shouldn’t be modified, for example actual
detected status
parameter, run record parameter etc.
2> This function code can’t be modified under run status and can be changed
after stopping running
ENTER
DATA
50.00
-F0- -F2- F2.00
F2.06
05.00
-F2-
Key-press
operation
order
Enter into
editing Status
display first-class
menu
Choose
F2 group
function
code
Function group
confirmation go
into second-class
menu
Choose
function
code
F2.06
Go back to
First-class
menu
Exit editing
status
Store modified
value,back to
second-class menu
Display next
function code
LEDdisplayed
content
05.00
F2.07 06.00
Function code
confirmation,
Enter into
third-class
menu
Parameter
modification,
Choose parameter
digit
Parameter
modification,
56
ESC
MENU
ENTER
DATA
ENTER
DATA
SHIFT
ENTER
DATA
ESC
MENU
ESC
MENU
LED displayed
content
1s
1s
50.00 C-01
Set frequency
Key-press
operation
order
Output frequency
Output current
Out
p
ut volta
g
e
Pulse input
Para. value C-02
Para. value
C-03
1s
parameterC-14
1s
parameter
∫…∫
SHIFT SHIFT
SHIFT SHIFT SHIFT