Service manual
www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 4 Run and operation explanation for inverter
37
(4) function code editing status
Under waiting, run or failure alarm status,press key,can enter into
editing status(If user password is set,can enter into editing status after inputting
the password,see also FF.00 description and Fig.4-10),and editing status is
displayed according to three classes menu mode,as shown in Fig. 4-5. To press
key can enter into one class by one class. Under function parameter
display status,to press key to carry on parameter storage operation;
To press key can only come back to
upper class menu without stroring
modified parameter.
Fig.4-5 keypad display status switching
(5) Special display function
You can change set frequency under supervision state directly when keypad
potentiometer is effective (F0.00=0) or keypad digital setting is effective
(F0.00=1). Here the inverter displays set frequency if it’s stop or displays output
frequency if it’s running. After set frequency stops changing for 1 second the
inverter will go back to normal display status.
4.2.5 Method for operating keypad
Can carry on various operation to the inverter through keypad,for example:
(1) Status parameter display switching:
After pressing key ,display C group status supervision parameter; after
displaying one supervision parameter code for 1 second, will display this
parameter value automatically.
electrification
ENTER
ENTER
MENU
Second-class
menu
First class menu
Third-class
menu
MENU/ESC
MENU /ESC
ENTER/DATAstore para.
Editing status
Waiting status
parameter Display or
run status parameter
display or failure alarm
display
Set frequency
Switch display
run parameter
Frequency
setting mode
Digital provision
MENU /ESC
ESC
MENU
ENTER
DATA
ENTER
DATA
ESC
MENU
SHIFT