Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 3 installation and wiring
24
(3) YCI terminal accepts analog voltage signal inputwiring mode as follows:
Fig.3-13 YCI terminal wiring diagram
Explanation: relation between YCI input voltage and set frequency is as following
figure:
1> when YCI input voltage is 0~10V:
2> when YCI input voltage is 0~5V:
(4) wiring of analog output terminals AO1, AO2
Analog output terminals AO1, AO2 connected to analog meter and kinds
of physical data can be indicated, thereinto AO1 can output current (4~20mA) or
voltage (0~10V) decided by slide switch JP6. Terminal wiring mode as Fig.3-13.
10V
5V
0V
V
f(Hz)
high limit frequency
(REV)
+high limit frequency
(FWD)
5V
2.5V
0V
V
f(Hz)
high limit frequency
(REV)
+ high limit frequency
(FWD)
+10V
VCI
GND
PE
EDS1000
0~+10
+
Or 0~+5V
Shielded wire close end grounded
YCI current input
YCI volt.
JP7
JP7
05V
010V