Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 3 Serial port RS485 communication protocol
175
Software version
query order
Query auxiliary
device software
version
15 00 00 no ~010F00000197\r 1
Table 5 Response state word meanings of reading inverter state command
Bit
Signification
description 0 1
Bit0 Stop/run state Stop Run
Bit1 Logo for under voltage Normal Under voltage
Bit2 FWD/REV run logo Forward run Reverse run
Bit3 Swing freq. run mode logo Ineffective Effective
Bit4 Common run mode logo Ineffective Effective
Bit5 Jog run mode logo No Jog
Bit6 PLC run mode logo No Yes
Bit7 Multi-step freq. run mode logo No Yes
Bit8 PI closed loop run mode logo No Yes
Bit9 Set counting value arriving logo No Yes
Bit10
Specified counting value arriving
logo
No Yes
Bit11~15 Reserved