Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 2 The manual of EDS1300 middle frequency inverter
157
F2.10
Principal subordinate
machine communication
frequency provision
proportion
0(%)500(%) 1(%) 100(%)
F2.11 LED display control 1
0000-1111
first bit: running time
0: not display
1: display
second bit: accumulative time
0: not display
1: display
third bit: input terminal status
0: not display
1: display
kilobit(fourth bit):
output terminal status
0: not display
1: display
1 0000
F2.12 LED display control 2
0000-1111
first bit: analog input VCI
0: not display
1: display
second bit: analog input YCI
0: not display
1: display
third bit: analog input CCI
0: not display
1: display
kilobit(fourth bit):
exterior pulse input
0: not display
1: display
1 1111
F2.13
Parameter operation
control
LED 1
st
bit:
0: all parameter allowed to be
modified
1: except this parameterall
other parameter not
allowed to be modified
2: except F0.01 and this
parameter, all other
parameter not allowed to be
modified
LED 2
nd
bit:
0: no action
1: restore default value
2: clear history failure record
LED 3
rd
bit:
0: lock all buttons
1: lock all buttons but not
STOP key
2: lock all buttons but not
, STOP key
3: lock all buttons but not
RUN, STOP key
4: lock all buttons but not
SHIFT, STOP key
1 0 ×