Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 2 The manual of EDS1300 middle frequency inverter
156
F2Auxiliary run function parameter group
Function
code
Name Set range
Min.
unit
Factory
default
Modificat
-ion
F2.00
Analog filter time
constant
0.0030.00s 0.01s 0.20s
F2.01
Forward reverse run
dead-section time
0.03600.0s 0.1s 0.1s
F2.02
Automatic energy
save run
0: no action
1: action
1 0 ×
F2.03 AVR function
0: no action
1: action all the time
2: no action only during Dec
1 0 ×
F2.04
Slip frequency
compensation
0150(%)0-no slip frequency
compensation
1 0 ×
F2.05 Carrier wave freq. 215.0K 0.1K
depend on
machine type
×
F2.06 Jog run frequency 1.01000.0Hz 0.1Hz 50.0Hz
F2.07 Jog Acc time 0.160.0s 0.1s 20.0s
F2.08 Jog Dec time 0.160.0s 0.1s 20.0s
F2.09
Frequency input
channel combination
0: VCICCI
1: VCICCI
2: YCICCI
3: RS485+YCI
4: VCIYCI
5: reserved
6: exterior pulse provision
CCI
7: exterior pulse provision
CCI
8: reserved
9: reserved
10: reserved
11: reserved
12: reserved
13: VCICCI any nonzero
value effective, VCI
preferred
14: reserved
15: RS485+CCI
16: RS485-CCI
17: RS485+VCI
18: RS485-VCI
19: RS485+keypad
potentiometer
20: RS485- keypad
potentiometer
21: VCI+ keypad
potentiometer
22: VCI- keypad potentiometer
23: CCI+ keypad
potentiometer
24: CCI- keypad potentiometer
25: reserved
26: reserved
27: reserved
28: reserved
1 0 ×