Service manual
www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 2 The manual of EDS1300 middle frequency inverter
154
Appendix 2 The manual of EDS1300 middle frequency inverter
1 Symbol description
× ---- parameter can’t be changed in process of running
○ ---- parameter can be changed in process of running
* ---- read-only parameter, unmodifiable
2 Function parameter schedule graph
F0-Basic run function parameter group
Function
code
Name Set range
Min.
unit
Factory
default
Modifica
-tion
F0.00
Frequency input
channel selection
0: keypad analog potentiometer setting
1: keypad digital setting
2: terminal UP/DOWN adjust setting
(stored after power off)
3: serial port setting(not stored after power off)
4: VCI analog setting (VCI-GND)
5: CCI analog setting (CCI-GND)
6: YCI analog setting (YCI-GND)
7: terminal pulse (PULSE) setting
8: combination setting
9: terminal UP/DOWN adjust setting
(not stored after power off)
1 1 ○
F0.01 Freq. digit setting Lower limit Freq.~upper limit Freq. 0.1Hz 1000.0Hz ○
F0.02
Run command
channel selection
0: keypad run control
1: terminal run command control
(keypad stop command ineffective)
2: terminal run command control
(keypad stop command effective)
3: serial port run command control
(keypad stop command ineffective)
4: serial port run command control
(keypad stop command effective)
1 0 ○
F0.03
Run direction
setting
1
st
bit: 0, forward run; 1, reserved
2
nd
bit: 0, reverse run allowed
1, reverse run banned
3
rd
bit: REV/JOG key selection
0: as reverse run key
1: as jog key
1 100 ○
F0.04
Acce/Dece mode
selection
0: linear accelerating decelerating mode
1: S curve accelerating decelerating mode
1 0 ×
F0.05
S curve start
section time
10.0(%)-50.0(%)(Acce/Dece time)
F0.05+F0.06≤90(%)
0.1(%) 20.0(%) ○
F0.06 S curve risetime
10.0(%)-70.0(%)(Acce/Dece time)
F0.05+F0.06≤90(%)
0.1(%) 60.0(%) ○
F0.07
Acce Dece time
unit
0: second
1: minute
1 0 ×
F0.08 Acce time 1 0.1-6000.0 0.1 90.0 ○
F0.09 Dece time 1 0.1-6000.0 0.1 90.0 ○
F0.10 Upper limit freq. Lower limit freq.-2500Hz 0.1Hz 1000.0Hz ×
F0.11 Lower limit freq. 0.00-Upper limit freq. 0.01Hz 0.00Hz ×
F0.12 Lower limit freq. 0: run at lower limit freq. 1 0 ×