Service manual

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual
153
F2.43 Wire disconnecting delay PID control 1 1
F2.44 Time of wire disconnecting delay 5000 5000
F3.00 Closed-loop run 0 1
F3.08 proportion gain KP 0.250 0.250
F3.09 KI Integral gain KI 0.010 0.010
F3.12 Deviation margin 1.0(%) 1.0
F3.20 PID proportion gain 2 0.300 0.300
F3.21 PID Integral gain 2 0.000 0.000
F3.22 PID parameter self adjustment basis 1 1
F3.30 Failure relayTA,TB, TCfunction selection 15 15
F5.01 Input terminal X2 function selection 0 11
F5.02 Input terminal X3 function selection 0 12
F5.10 Closed-loop run 0 2
F5.15 proportion gain KP 2.60Hz 3.00Hz
F5.16 KI Integral gain KI 0.01Hz 0.01Hz
F7.03 Deviation margin 50.00 75.00